The Petroleum Quality Institute of America (PQIA) is an independent resource for information and insights on the quality of lubricants in the marketplace. Our mission is to serve the consumer of lubricants by randomly sampling and independently testing lubricants taken from the field. Test results are posted along with the brand names on the PQIA website. This webpage provides an analysis on the brand detailed below.
The following are the test results for the sample examined.
Manufactured By: Everclear of Ohio, Ltd., Youngstown, OH
Purchased at: Munster, IN
Date of purchase: 11/15/2016
Website(s): everclearmotoroil.weebly.com
Whereas this product is labeled as "Useful in a variety of automatic transmissions," the results of the tests conducted on this sample show a product that DOES NOT meet any recognized specification of Automatic Transmission Fluid.
The Brookfield Viscosity is 251% higher than the maximum viscosity specification for Dexron® III and Mercon® fluids. Also, the Viscosity at 100⁰C is 12% lower than the minimum specified for Dexron III and Mercon fluids. In addition, the Flash Point is lower than required for Dexron III and Mercon fluids. Furthermore, the organometallic additive levels in this sample indicate the product may be contaminated with used oil and abrasive material. Use of this product in modern automatic transmissions will likely cause harm.
This is the fourteenth time PQIA has issued Consumer Alerts on lubricants marketed under the Everclear brand. This product has been ordered off the shelves in the states of Georgia and North Carolina.
![]() |
Physical Properties | ![]() |
Elemental Analysis | ![]() |
|
Labeling | ![]() |
Note: Although the laboratory tests conducted cannot alone be used to establish if an Automatic Transmission Fluid meets all of its labeled specifications, they can be used to determine if it doesn't.
PHYSICAL TESTS (click for test details) - a | Standard | Everclear |
Flash Point in ºC (ASTM D92) | 170/177 Min-c | |
Viscosity @ 100ºC, cSt (ASTM D445) | 6.8 Min | |
Viscosity @40ºC, cSt (ASTM D445) | 34.0 | |
Viscosity Index (ASTM D2270) | 122 | |
Brookfield Viscosity @-40ºC mPa s (cP) | 20,000 Max | |
ELEMENTAL ANALYSIS (click for test details) - a, b | ||
Additives | ||
Calcium | 6 | |
Magnesium | 2 | |
Phosphorus, ppm | 209 | |
Zinc, ppm | 3 | |
Molybdenum, ppm | 0 | |
Barium, ppm | 0 | |
Boron, ppm | 0 | |
Silicon, ppm | ||
Potassium, ppm | 1 | |
Manganese, ppm | 0 | |
Titanium, ppm | 0 | |
Copper, ppm | ||
Sodium, ppm | 1 | |
Vanadium, ppm | 0 | |
Contaminants | ||
Silver, ppm | 0 | |
Aluminum, ppm | 4 | |
Chromium, ppm | 0 | |
Iron, ppm | ||
Nickel, ppm | 0 | |
Lead, ppm | 1 | |
Antimony, ppm | 0 | |