Home

Product Tested

front label

Click above for larger image

back label

Click above for larger image

Golden Lubricants LLC

Company and Product Information

Corporate Office:
Golden Lubricants LLC
1333 Burr Ridge Pkwy Suite 200 
Burr Ridge, IL 60527

Website(s): www.morgasoil.com

 

MORGAS ATF D/M

Product: MORGAS
Labeled: ATF D/M

Distributed By: Golden Lubricants LLC, Burr Ridge, IL

Purchased at: Ford Heights, IL

Date of purchase: 11/15/2016

 

Website(s): www.morgasoil.com

Test Results and Assessment:

Advisory: The MORGAS ATF D/M label states that the product is suitable for use in transmissions where DEXRON® III or MERCON® is specified.  PQIA's test results for this sample do not meet the DEXRON III and MERCON specification for Flash Point and kinematic viscosity at 100ºC. The kinematic viscosity at 100ºC is 22% lower than the minimum specified for DEXRON III/MERCON automatic transmission fluids, and the Flash Point is 12% lower than the minimum temperature specified for MERCON automatic transmission fluids. The organometallic additive levels are not typical of that in a DEXRON III/MERCON.

bottle icon Physical Properties pass
Elemental Analysis pass
Labeling warning
Flash Point of a DEXRON III/MERCON Fluid in °C (ASTM D92)

The Flash Point is 12% lower than the minimum temperature specified for MERCON automatic transmission fluids.
FusionCharts XT will load here!
Viscosity @ 100°C, cSt (ASTM D445)

The kinematic viscosity at 100ºC is 22% lower than the minimum specified for DEXRON III/MERCON automatic transmission fluids.
FusionCharts XT will load here!
Brookfield Viscosity @-40°C mPa s (cP)

The results of the Brookfield viscosity test conducted on this sample meet the requirements of Dexron III/Mercon.
FusionCharts XT will load here!

Note1: Although laboratory tests alone cannot be used to establish if engine oil meets an API Service Category, they can be used to determine if it doesn't. Note2: The specifications for flash point and viscosity @ 100°C include only minimum values; the maximum values shown in the “standard” area of the chart are truncated for illustrative purposes.

PHYSICAL TESTS (click for test details) - a Standard MORGAS
Flash Point in ºC (ASTM D92) 170/177 Min-c 155
Viscosity @ 100ºC, cSt (ASTM D445) 6.8 Min 5.3
Viscosity @40ºC, cSt (ASTM D445)   25.4
Viscosity Index (ASTM D2270) 148
Brookfield Viscosity @-40ºC mPa s (cP) 20,000 Max 13,020
ELEMENTAL ANALYSIS (click for test details) - a, b
Additives
Calcium, ppm 1,027
Magnesium, ppm 5
Phosphorus, ppm   404
Zinc, ppm 435
Molybdenum,  ppm 2
Barium, ppm 0
Boron, ppm 4
Silicon, ppm 6
Potassium, ppm 1
Manganese, ppm 0
Titanium, ppm 0
Copper, ppm 1
Sodium, ppm 0
Vanadium, ppm 0
Contaminants
Silver, ppm 0
Aluminum, ppm 0
Chromium, ppm 0
Iron, ppm 0
Nickel, ppm 0
Lead, ppm 0
Antimony, ppm 0
Tin, ppm 0
  1. Standards, shown in yellow are established by API, SAE and others.
  2. Test Method for metal analysis is ASTM D5185.
  3. Dexron® III, 170°C minimum, Mercon®, 177°C minimum.