Home

Product Tested

front label

Click above for larger image

back label

Click above for larger image

MileMaster Lubricants

Company and Product Information

Corporate Office:
MileMaster
1293 Eldridge Pkwy
Houston, TX 77077

Website(s): www.milemasterlubes.com

 

MileMaster ATF
Multi-Purpose

Product: MileMaster ATF
Labeled: Multi-Purpose
DEXRON -III or MERCON

Manufactured For: MileMaster Lubricants, Houston, TX

Purchased at: Paw Paw, MI

Date of purchase: 12-11-2016

 

Website(s): www.milemasterlubes.com

Test Results and Assessment:

The results of the tests conducted on this sample meet the requirements for DEXRON® III/MERCON®.

bottle icon Physical Properties pass
Elemental Analysis pass
Labeling warning
Flash Point of a DEXRON III/MERCON Fluid in °C (ASTM D92)

The results of the Flash Point test conducted on this sample meet the requirements of Dexron III/Mercon.
FusionCharts XT will load here!
Viscosity @ 100°C, cSt (ASTM D445)

The results of the Kinematic Viscosity @ 100ºC test conducted on this sample meet the requirements of Dexron III/Mercon.
FusionCharts XT will load here!
Brookfield Viscosity @-40°C mPa s (cP)

The results of the Brookfield viscosity test conducted on this sample meet the requirements of Dexron III/Mercon.
FusionCharts XT will load here!

Note1: Although laboratory tests alone cannot be used to establish if engine oil meets an API Service Category, they can be used to determine if it doesn't. Note2: The specifications for flash point and viscosity @ 100°C include only minimum values; the maximum values shown in the “standard” area of the chart are truncated for illustrative purposes.

PHYSICAL TESTS (click for test details) - a Standard MileMaster
Flash Point in ºC (ASTM D92) 170/177 Min-c 210
Viscosity @ 100ºC, cSt (ASTM D445) 6.8 Min 6.9
Viscosity @40ºC, cSt (ASTM D445)   34.3
Viscosity Index (ASTM D2270) 166
Brookfield Viscosity @-40ºC mPa s (cP) 20,000 Max 16,800
ELEMENTAL ANALYSIS (click for test details) - a, b
Additives
Calcium, ppm 3
Magnesium, ppm 0
Phosphorus, ppm   136
Zinc, ppm 0
Molybdenum,  ppm 0
Barium, ppm 0
Boron, ppm 54
Silicon, ppm 0
Potassium, ppm 0
Manganese, ppm 0
Titanium, ppm 0
Copper, ppm 0
Sodium, ppm 0
Vanadium, ppm 0
Contaminants
Silver, ppm 0
Aluminum, ppm 0
Chromium, ppm 0
Iron, ppm 0
Nickel, ppm 0
Lead, ppm 0
Antimony, ppm 0
Tin, ppm 0
  1. Standards, shown in yellow are established by API, SAE and others.
  2. Test Method for metal analysis is ASTM D5185.
  3. Dexron® III, 170°C minimum, Mercon®, 177 °C minimum.