Test Results and Assessment:


Use of this product in virtually all automobiles will likely cause harm to the transmission. 

Whereas this product is labeled as "a general purpose automatic transmission fluid capable of being used in a wide range of automatic transmissions," the results of the tests conducted on this sample shows otherwise. The product  DOES NOT meet any recognized specifications for Automatic Transmission Fluid (ATF) and would likely not meet the requirements for any cars currently on the road. Moreover, the test results on the sample indicate that use of this product in virtually any car or truck currently on the road will likely cause harm to the transmission.

Although the product does not claim to meet any ATF specifications, if compared to those of DEXRON®-III and MERCON®  (commonly seen in the market), the Brookfield Viscosity is 221% higher than the maximum viscosity for the specifications. In addition, the Viscosity at 100⁰C is 15% lower than the minimum specified. Furthermore, the spectrographic analysis of the sample shows silicon, copper, aluminum, and iron at levels that indicate the product may be contaminated with used oil and abrasive material.

Note: The label on this product does not show the name or address of the manufacturer, packer, or distributor. This information is required to comply with the Uniform Packaging and Labeling Regulations in NIST Handbook 130 which states "Any package kept, offered, or exposed for sale, or sold at any place other than on the premises where packed shall specify conspicuously on the label of the package the name and address of the manufacturer, packer, or distributor. The name shall be the actual corporate name, or, when not incorporated, the name under which the business is conducted.  The address shall include street address, city, state (or country if outside the United States), and ZIP Code (or the mailing code, if any, used in countries other than the United States); however, the street address may be omitted if it is listed in any readily accessible, well-known, widely published, and publicly available resource, including but not limited to a printed directory, electronic database, or website."

bottle icon Physical Properties pass
Elemental Analysis pass
Labeling warning

Test results of Mileage 365 ATF as compared to DEXRON®-III and MERCON® specifications.

Flash Point of a DEXRON III/MERCON Fluid in °C (ASTM D92)

The results of the Flash Point test conducted on this sample meet the requirements of DEXRON®-III and MERCON®.
FusionCharts XT will load here!
Viscosity @ 100°C, cSt (ASTM D445)

The Viscosity at 100°C is 15% lower than the minimum specified for DEXRON®-III and MERCON® fluids.
FusionCharts XT will load here!
Brookfield Viscosity @-40°C mPa s (cP)

The Brookfield Viscosity is 221% higher than the maximum viscosity specification for DEXRON®-III and MERCON® fluids.
FusionCharts XT will load here!
PHYSICAL TESTS (click for test details) - a Standard Mileage 365
Flash Point in ºC (ASTM D92) 170/177 Min-c 187
Viscosity @ 100ºC, cSt (ASTM D445) 6.8 Min 5.8
Viscosity @40ºC, cSt (ASTM D445)   30.7
Viscosity Index (ASTM D2270) 134
Brookfield Viscosity @-40ºC mPa s (cP) 20,000 Max 64,134
ELEMENTAL ANALYSIS (click for test details) - a, b
Additives
Calcium, ppm 6
Magnesium, ppm 2
Phosphorus, ppm   211
Zinc, ppm 4
Molybdenum,  ppm 1
Barium, ppm 0
Boron, ppm 0
Silicon, ppm 219
Potassium, ppm 0
Manganese, ppm 0
Titanium, ppm 0
Copper, ppm 58
Sodium, ppm 0
Vanadium, ppm 0
Contaminants
Silver, ppm 0
Aluminum, ppm 7
Chromium, ppm 0
Iron, ppm 56
Nickel, ppm 0
Lead, ppm 3
Antimony, ppm 0
Tin, ppm 0
  1. Standards, shown in yellow are established by API, SAE and others.
  2. Test Method for metal analysis is ASTM D5185.
  3. DEXRON® III, 170°C minimum, MERCON®, 177°C minimum.