Home

Product Tested

front label

Click above for larger image

back label

Click above for larger image

GH Berlin-Windward, A Brenntag Company

Company and Product Information

Corporate Office:
GH Berlin-Windward, A Brenntag Company
1064 Goffs Falls Rd
Manchester, NH 03103

Website(s):   www.ghberlinwindward.com

 

Navi Guard ATF
Multi Purpose D/M

Product: Navi Guard
Labeled: Multi Purpose ATF D/M

Distributed By: GH Berlin-Windward, A Brenntag Company

Purchased at: Binghamton, NY

Date of purchase: 2/16/2017

 

Website(s):  www.ghberlinwindward.com

Test Results and Assessment:

The results of the tests conducted on this sample meet the requirements for DEXRON® III/MERCON®.

bottle icon Physical Properties pass
Elemental Analysis pass
Labeling warning
Flash Point of a DEXRON III/MERCON Fluid in °C (ASTM D92)

The results of the Flash Point test conducted on this sample meet the requirements of Dexron III/Mercon.
FusionCharts XT will load here!
Viscosity @ 100°C, cSt (ASTM D445)

The results of the Kinematic Viscosity @ 100ºC test conducted on this sample meet the requirements of Dexron III/Mercon.
FusionCharts XT will load here!
Brookfield Viscosity @-40°C mPa s (cP)

The results of the Brookfield viscosity test conducted on this sample meet the requirements of Dexron III/Mercon.
FusionCharts XT will load here!

Note1: Although laboratory tests alone cannot be used to establish if engine oil meets an API Service Category, they can be used to determine if it doesn't. Note2: The specifications for flash point and viscosity @ 100°C include only minimum values; the maximum values shown in the “standard” area of the chart are truncated for illustrative purposes.

PHYSICAL TESTS (click for test details) - a Standard Navi Guard
Flash Point in ºC (ASTM D92) 170/177 Min-c 219
Viscosity @ 100ºC, cSt (ASTM D445) 6.8 Min 7.0
Viscosity @40ºC, cSt (ASTM D445)   34.3
Viscosity Index (ASTM D2270) 171
Brookfield Viscosity @-40ºC mPa s (cP) 20,000 Max 16,400
ELEMENTAL ANALYSIS (click for test details) - a, b
Additives
Calcium, ppm 135
Magnesium, ppm 7
Phosphorus, ppm   241
Zinc, ppm 31
Molybdenum,  ppm 0
Barium, ppm 0
Boron, ppm 98
Silicon, ppm 3
Potassium, ppm 3
Manganese, ppm 0
Titanium, ppm 0
Copper, ppm 0
Sodium, ppm 9
Vanadium, ppm 0
Contaminants
Silver, ppm 0
Aluminum, ppm 0
Chromium, ppm 0
Iron, ppm 0
Nickel, ppm 0
Lead, ppm 0
Antimony, ppm 0
Tin, ppm 0
  1. Standards, shown in yellow are established by API, SAE and others.
  2. Test Method for metal analysis is ASTM D5185.
  3. DEXRON® III, 170°C minimum, MERCON®, 177°C minimum.