Home

Product Tested

front label

Click above for larger image

back label

Click above for larger image

Vantage Brands LLC

Company and Product Information

Corporate Office:
Vantage Brands LLC
121 HWY 36, Suite 180
West Long Branch, NJ 07764

Website(s): www.thevantagebrand.com

PETROLEUM QUALITY INSTITUTE OF AMERICA TEST PROGRAM

The Petroleum Quality Institute of America (PQIA) is an independent resource for information and insights on the quality of lubricants in the marketplace. Our mission is to serve the consumer of lubricants by randomly sampling and independently testing lubricants taken from the field. Test results are posted along with the brand names on the PQIA website. This webpage provides an analysis on the brand detailed below.

The following are the test results for the sample examined.

Vantage 5W-30
SAE Synthetic Blend Oil

Product: Vantage
Viscosity Grade: SAE 5W-30
Labeling: API SN/ILSAC GF-5

Manufactured By: Vantage Brands LLC, West Long Branch, NJ

Purchased at: Ypsilanti, MI

Date of purchase: 11/15/2016

 

Website(s): www.thevantagebrand.com

Test Results and Assessment:

The results of the tests conducted on this sample meet the SAE J300 specifications for the SAE Viscosity Grade listed on the product label, and are consistent with the listed API Service Categories.

bottle icon Physical Properties pass
Elemental Analysis pass
Labeling warning

Note: Although laboratory tests alone cannot be used to establish if engine oil meets an API Service Category, they can be used to determine if it doesn't.

PHYSICAL TESTS (click for test details) - a Standard Vantage
TBN, mg KOH/g (ASTM D2896) 8.8
Viscosity @ 100ºC, cSt (ASTM D445) 9.3 to <12.5 10.35
Viscosity @40ºC, cSt (ASTM D445) 62.48
Viscosity Index (ASTM D2270) 154
Viscosity @-30ºC mPa s (cP) (ASTM D5293) 6,600 Max 6,528
Volatility, mass % loss, 1 hr, @ 250ÂșC (ASTM D5800) 15 Max -c 12.8
ELEMENTAL ANALYSIS (click for test details) - a, b
Additives
Calcium, ppm 2,547
Magnesium, ppm 11
Phosphorus, ppm 600 to 800 -d 802
Zinc, ppm 853
Molybdenum,  ppm 46
Barium, ppm <1
Boron, ppm 2
Silicon, ppm 6
Potassium, ppm <5
Manganese, ppm <1
Titanium, ppm <1
Copper, ppm <1
Sodium, ppm <5
Vanadium, ppm <1
Contaminants
Silver, ppm <1
Aluminum, ppm 1
Chromium, ppm <1
Iron, ppm <1
Nickel, ppm <1
Lead, ppm <1
Antimony, ppm <1
Tin, ppm <1
  1. Standards, shown in yellow are established by API, SAE and others.
  2. Test Method for metal analysis is ASTM D5185.
  3. This specification is expressed to two significant figures, therefore results up to 15.5 are considered on specification.
  4. This specification is expressed to one significant figure, therefore results between 550 and 849 are considered on specification.